{
 "type": "mcp",
 "name": "SparkQuote NEC calculators",
 "registry_name": "ai.sparkquote/nec-calculators",
 "also_published_as": [],
 "description": "NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.",
 "url": "https://sparkquote.ai/mcp",
 "transport": "streamable-http",
 "website": "https://sparkquote.ai/tools/mcp-server",
 "repo": null,
 "ours": false,
 "publisher": "ai.sparkquote",
 "categories": [
  "calculators",
  "engineering",
  "finance"
 ],
 "tests": {
  "tested_at": "2026-11-26T10:29:38.280Z",
  "http_status": 200,
  "initialize": "ok",
  "tools_list": "ok",
  "tool_count": 10,
  "latency_ms": 140,
  "tools_list_ms": 105,
  "protocol_version": "2025-06-18",
  "oauth_discovery": null,
  "server_info": {
   "name": "sparkquote",
   "version": "1.0.0"
  },
  "error": null
 },
 "signals": {
  "github_stars": null,
  "license": null,
  "repo_pushed_at": null,
  "repo_archived": null,
  "npm_downloads_30d": null,
  "adoption_note": null,
  "registry_updated_at": "2026-10-14T20:16:48.737033Z",
  "registry_published_at": "2026-10-14T20:16:48.737033Z",
  "pypi_downloads": "missing"
 },
 "checks": {
  "latency": 100,
  "tool_docs": 100,
  "breadth": 61,
  "freshness": 75,
  "license": "missing",
  "adoption": "missing",
  "protocol": 100
 },
 "score": 52.3,
 "missing": [
  "license",
  "adoption"
 ],
 "tools": [
  "wire_size",
  "voltage_drop",
  "watts_to_amps",
  "conduit_fill",
  "box_fill",
  "load_calculator",
  "ohms_law",
  "panel_schedule",
  "bid_calculator",
  "nec_ampacity"
 ],
 "tool_docs": [
  {
   "n": "wire_size",
   "d": "Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over th"
  },
  {
   "n": "voltage_drop",
   "d": "Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 "
  },
  {
   "n": "watts_to_amps",
   "d": "Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value."
  },
  {
   "n": "conduit_fill",
   "d": "Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5."
  },
  {
   "n": "box_fill",
   "d": "Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conduc"
  },
  {
   "n": "load_calculator",
   "d": "Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or co"
  },
  {
   "n": "ohms_law",
   "d": "Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated."
  },
  {
   "n": "panel_schedule",
   "d": "Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance."
  },
  {
   "n": "bid_calculator",
   "d": "Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin))."
  },
  {
   "n": "nec_ampacity",
   "d": "Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), befor"
  }
 ],
 "passed": true,
 "auth_required": false,
 "fail_reason": null,
 "category_confidence": 0.945,
 "category_source": "classifier",
 "category_confirmed": false,
 "category_scores": {
  "calculators": 7,
  "engineering": 0.6,
  "productivity": 0.24,
  "legal": 0.24
 },
 "subcategory": null,
 "id": "ai-sparkquote-nec-calculators",
 "listing": {
  "plan": "curated",
  "fee_usd": null,
  "note": "Listing fees are not active. Placement is earned only by test results."
 },
 "search_keywords": "sparkquoteneccalculators ai sparkquote nec calculators ai.sparkquote/nec-calculators ai sparkquote nec-calculators aisparkquoteneccalculators sparkquote.ai sparkquote ai sparkquote",
 "status": "listed",
 "first_seen": "2026-11-24",
 "uptime_days": "3/3",
 "liveness": {
  "last_handshake": "2026-11-26T10:29:38.280Z",
  "tool_list_sha256": "b53d4ec4847b9ee28c03583cf175c0abac1e53794ca2e85dc24dcd52cb0cb31c",
  "error_rate_7d": "missing",
  "window_days": 7,
  "signed": false,
  "note": "This directory already re-tests listings daily. A 7-day per-tool error history is not stored on the Free-plan Status DO, so error_rate_7d is missing until that history exists."
 },
 "fmf_paid": {
  "note": "Paid data only FMF Tools has, pay per call with x402 (Base USDC) or MPP (Tempo); no signup",
  "etsy_movers": {
   "what": "Today's top 20 Etsy shops by sales acceleration from the FMF Tools Etsy Pulse panel (no input)",
   "endpoint": "https://etsy-movers.fmf-x402.workers.dev/etsy/movers/today",
   "price_usd": 0.01,
   "example": "GET https://etsy-movers.fmf-x402.workers.dev/etsy/movers/today -> 402 challenge; pay, retry -> {shops:[...20]}",
   "mcp": "https://etsy-movers.fmf-x402.workers.dev/mcp"
  },
  "recipes": {
   "what": "Which paid API to call for an agent task",
   "endpoint": "https://agent-recipes.fmf-x402.workers.dev/mpp/recipes/find",
   "price_usd": 0.003
  }
 },
 "health": {
  "last_verified": "2026-11-26T10:29:38.280Z",
  "tool_count": 10,
  "latency_ms_daily_test": 140,
  "price_range_usd": null,
  "uptime_7d": 1,
  "uptime_30d": 1,
  "checks_7d": 4,
  "p50_latency_ms_7d": 457,
  "last_checked": "2026-11-26T10:29:38.280Z",
  "last_30_days": "...........................11.",
  "history_since": "2026-11-25"
 },
 "install": "https://tools.fmf-x402.workers.dev/api/install/ai-sparkquote-nec-calculators",
 "maintainer_verified": false,
 "badge": {
  "svg": "https://tools.fmf-x402.workers.dev/badge/ai-sparkquote-nec-calculators.svg",
  "markdown": "[![FMF Tools: tested](https://tools.fmf-x402.workers.dev/badge/ai-sparkquote-nec-calculators.svg)](https://tools.fmf-x402.workers.dev/tool/ai-sparkquote-nec-calculators?ref=badge)"
 }
}