 "type": "mcp",
 "name": "EngScript Engineering MCP",
 "registry_name": "com.engscript/mcp",
 "also_published_as": [],
 "description": "Engineering calculation MCP server for oil and gas engineering applications.",
 "url": "https://engscript.com/mcp",
 "transport": "streamable-http",
 "website": null,
 "repo": null,
 "ours": false,
 "publisher": "com.engscript",
 "categories": [
  "engineering",
  "research",
  "dev-tools"
 ],
 "tests": {
  "tested_at": "2026-11-24T21:35:58.584Z",
  "http_status": 200,
  "initialize": "ok",
  "tools_list": "ok",
  "tool_count": 60,
  "latency_ms": 369,
  "tools_list_ms": 449,
  "protocol_version": "2025-06-18",
  "oauth_discovery": null,
  "server_info": {
   "name": "engscript",
   "version": "1.0.0"
  },
  "error": null
 },
 "signals": {
  "github_stars": null,
  "license": null,
  "repo_pushed_at": null,
  "repo_archived": null,
  "npm_downloads_30d": null,
  "adoption_note": null,
  "registry_updated_at": "2026-08-14T05:11:03.283795Z",
  "registry_published_at": "2026-08-14T05:11:03.283795Z",
  "pypi_downloads": "missing"
 },
 "checks": {
  "latency": 97.4,
  "tool_docs": 100,
  "breadth": 100,
  "freshness": 50,
  "license": "missing",
  "adoption": "missing",
  "protocol": 100
 },
 "score": 52.1,
 "missing": [
  "license",
  "adoption"
 ],
 "tools": [
  "MIXTURE",
  "CARBON",
  "STEAM",
  "PSYCHROMETRIC",
  "FUELGAS",
  "FLUEGAS",
  "EMISSIONFACTOR",
  "REFRIGERANT",
  "PTV",
  "MtoV",
  "VtoM",
  "Pmean",
  "PIPEFF",
  "STEAMPH",
  "STEAMLEAK",
  "PIPEINSUL",
  "PIPESTEAM",
  "PIPEWATER",
  "PIPEAIR",
  "PIPENITROGEN",
  "PIPEFLOWGAS",
  "PIPEFLOWLIQ",
  "CVGAS",
  "CVLIQ",
  "CVSTEAM",
  "ORIFICEGAS",
  "ORIFICELIQ",
  "VENTURIGAS",
  "VENTURILIQ",
  "PSVGAS",
  "PSVSTEAM",
  "PSVLIQ",
  "PUMPBHP",
  "COMPPOLYEFF",
  "TBNEFF",
  "STGEFF",
  "HTRINOUTEFF",
  "HTRLOSSEFF",
  "HEXRF_KD",
  "HEXRF",
  "HEXRF_DG",
  "LMTD",
  "STEAMFLASH",
  "DESUPERHEATER",
  "HPADEPRESS",
  "GN2DEPRESS",
  "LN2DEPRESS",
  "STMDEPRESS",
  "CTWREVAPOR",
  "CTWRLG",
  "CTWRNTU",
  "CTWRCAPA",
  "CTWRCAPADSNTST",
  "DVR",
  "advDVR",
  "BALANCE",
  "FORMULA",
  "SOLVE",
  "ECONOMIC",
  "advECONOMIC"
 ],
 "tool_docs": [
  {
   "n": "MIXTURE",
   "d": "Primary thermodynamic property calculator. Use this tool first for all mixture property calculations. Supports hydrocarbons and non-hydrocarbon chemicals (PR EO"
  },
  {
   "n": "CARBON",
   "d": "Calculate thermodynamic properties of hydrocarbon mixture. Supports hydrocarbons and non-hydrocarbon chemicals (PR EOS flash calculation)."
  },
  {
   "n": "STEAM",
   "d": "Calculate thermodynamic and transport properties of steam based on IAPWS"
  },
  {
   "n": "PSYCHROMETRIC",
   "d": "Psychrometric properties of moist air"
  },
  {
   "n": "FUELGAS",
   "d": "Calculate MW, LHV and HHV of fuel gas from composition"
  },
  {
   "n": "FLUEGAS",
   "d": "Calculate enthalpy of flue gas from composition"
  },
  {
   "n": "EMISSIONFACTOR",
   "d": "Calculate CO2 emission conversion factor from gas composition"
  },
  {
   "n": "REFRIGERANT",
   "d": "Calculate refrigerant thermodynamic properties using CoolProp. Provide Fluid name and any 2 state variables from: T, P, rho, H, S, U. Returns all remaining prop"
  },
  {
   "n": "PTV",
   "d": "Calculate gas molar volume using equation of state"
  },
  {
   "n": "MtoV",
   "d": "Convert mass flow rate to volumetric flow rate at standard condition"
  },
  {
   "n": "VtoM",
   "d": "Convert volumetric flow rate to mass flow rate at standard condition and normal condition Sm3/hr, Nm3/hr, SCFH"
  },
  {
   "n": "Pmean",
   "d": "Calculate mean pressure between inlet and outlet"
  },
  {
   "n": "PIPEFF",
   "d": "Calculate Darcy friction factor based on Reynolds number and pipe roughness"
  },
  {
   "n": "STEAMPH",
   "d": "Calculate mass flow from pin-hole on the steam piping"
  },
  {
   "n": "STEAMLEAK",
   "d": "Calculate steam leak mass flow and flow condition (CHOKED / SUBCRITICAL) based on upstream and downstream conditions"
  },
  {
   "n": "PIPEINSUL",
   "d": "Calculate optimal pipe insulation thickness to limit outer surface temperature (burn protection) and minimise heat loss. Uses cylindrical heat conduction + exte"
  },
  {
   "n": "PIPESTEAM",
   "d": "Calculate steam pipe sizing: pipe diameter, velocity, pressure drop"
  },
  {
   "n": "PIPEWATER",
   "d": "Calculate water pipe sizing: pipe diameter, velocity, pressure drop"
  },
  {
   "n": "PIPEAIR",
   "d": "Calculate compressed air pipe sizing: pipe diameter, velocity, pressure drop"
  },
  {
   "n": "PIPENITROGEN",
   "d": "Calculate nitrogen pipe sizing: pipe diameter, velocity, pressure drop"
  },
  {
   "n": "PIPEFLOWGAS",
   "d": "Calculate isothermal gas pipe flow: density, volumetric flow rate, mass flow rate from pressure drop"
  },
  {
   "n": "PIPEFLOWLIQ",
   "d": "Calculate liquid pipe flow: volumetric flow rate and mass flow rate from pressure drop"
  },
  {
   "n": "CVGAS",
   "d": "Calculate gas control valve Cv and Kv from flow conditions"
  },
  {
   "n": "CVLIQ",
   "d": "Calculate liquid control valve Cv and Kv from flow conditions"
  },
  {
   "n": "CVSTEAM",
   "d": "Calculate steam control valve Cv and Kv from flow conditions"
  },
  {
   "n": "ORIFICEGAS",
   "d": "Gas orifice sizing / differential pressure / flow rate calculation based on ISO 5167 orifice. Exactly ONE of [M, dP, D2] must be set to '?' — that variable will"
  },
  {
   "n": "ORIFICELIQ",
   "d": "Liquid orifice sizing / differential pressure / flow rate calculation based on ISO 5167 orifice. Exactly ONE of [M, dP, D2] must be set to '?' — that variable w"
  },
  {
   "n": "VENTURIGAS",
   "d": "Gas Venturi tube sizing / differential pressure / flow rate calculation based on ISO 5167 Venturi meter (as cast convergent venturi tube). Exactly ONE of [M, dP"
  },
  {
   "n": "VENTURILIQ",
   "d": "Liquid Venturi tube sizing / differential pressure / flow rate calculation based on ISO 5167 Venturi meter (as cast convergent venturi tube). Exactly ONE of [M,"
  },
  {
   "n": "PSVGAS",
   "d": "Calculate required PSV (pressure safety valve) relief area for gas/vapor service per API 520"
  },
  {
   "n": "PSVSTEAM",
   "d": "Calculate required PSV (pressure safety valve) relief area for steam service per API 520"
  },
  {
   "n": "PSVLIQ",
   "d": "Calculate required PSV (pressure safety valve) relief area for liquid service per API 520"
  },
  {
   "n": "PUMPBHP",
   "d": "Calculate pump brake horsepower"
  },
  {
   "n": "COMPPOLYEFF",
   "d": "Calculate polytropic efficiency of compressor"
  },
  {
   "n": "TBNEFF",
   "d": "Calculate steam turbine isentropic efficiency"
  },
  {
   "n": "STGEFF",
   "d": "Calculate multistage steam turbine isentropic efficiency"
  },
  {
   "n": "HTRINOUTEFF",
   "d": "Calculate fired heater heat duty and efficiency from inlet/outlet conditions and composition"
  },
  {
   "n": "HTRLOSSEFF",
   "d": "Calculate fired heater loss efficiency from ambient temperature, stack gas temperature and excess oxygen"
  },
  {
   "n": "HEXRF_KD",
   "d": "Heat exchanger fouling resistance back-calculation from shell/tube-side operating conditions using Kern + Dittus-Boelter."
  },
  {
   "n": "HEXRF",
   "d": "Heat exchanger fouling resistance back-calculation from shell/tube-side operating conditions using Kern + Dittus-Boelter."
  },
  {
   "n": "HEXRF_DG",
   "d": "Heat exchanger fouling resistance back-calculation from shell/tube-side operating conditions using Delaware + Gnielinski."
  },
  {
   "n": "LMTD",
   "d": "Calculate LMTD of heat exchanger"
  },
  {
   "n": "STEAMFLASH",
   "d": "Calculate flash steam flow from pressure reduction"
  },
  {
   "n": "DESUPERHEATER",
   "d": "Calculate boiler feed water flow and total flow from pressure and temperature reduction through desuperheater. Also returns the inlet/outlet/BFW specific enthal"
  },
  {
   "n": "HPADEPRESS",
   "d": "Calculate depressurization gas volume and hold time for high pressure air storage vessel"
  },
  {
   "n": "GN2DEPRESS",
   "d": "Calculate depressurization gas volume and hold time for gaseous nitrogen storage vessel"
  },
  {
   "n": "LN2DEPRESS",
   "d": "Calculate depressurization gas volumn abd hold time and saturation temperature for liquid nitrogen storage vessel"
  },
  {
   "n": "STMDEPRESS",
   "d": "Calculate depressurization steam volumn and hold time for steam accumulator"
  },
  {
   "n": "CTWREVAPOR",
   "d": "Cooling tower evaporation rate: mass removal rate (MR) and heat removal rate (QR)"
  },
  {
   "n": "CTWRLG",
   "d": "Cooling tower L/G ratio calculation"
  },
  {
   "n": "CTWRNTU",
   "d": "Cooling tower NTU and characteristic C value calculation"
  },
  {
   "n": "CTWRCAPA",
   "d": "Cooling tower capacity evaluation"
  },
  {
   "n": "CTWRCAPADSNTST",
   "d": "Cooling tower capacity evaluation: design vs test"
  },
  {
   "n": "DVR",
   "d": "Data Validation and Reconciliation"
  },
  {
   "n": "advDVR",
   "d": "Advanced Data Validation and Reconciliation including gross error detection and elimation"
  },
  {
   "n": "BALANCE",
   "d": "General mass/energy balance solver using GEKKO"
  },
  {
   "n": "FORMULA",
   "d": "Generic formula calculator with unit conversion and IF-THEN-ELSE"
  },
  {
   "n": "SOLVE",
   "d": "Solve nonlinear equations with unknown variables using fsolve"
  },
  {
   "n": "ECONOMIC",
   "d": "Economic analysis: NPV, IRR, Simple Payback, Profitability Index, EAC"
  },
  {
   "n": "advECONOMIC",
   "d": "Advanced Economic analysis with inflation, depreciation, and tax: NPV, IRR, Simple Payback, Profitability Index, NCF"
  }
 ],
 "passed": true,
 "auth_required": false,
 "fail_reason": null,
 "category_confidence": 0.974,
 "category_source": "classifier",
 "category_scores": {
  "engineering": 6,
  "calculators": 3.73,
  "agent-infra": 2,
  "devops": 0.8
 },
 "subcategory": null,
 "id": "com-engscript-mcp",
 "listing": {
  "plan": "curated",
  "fee_usd": null,
  "note": "Listing fees are not active. Placement is earned only by test results."
 },
 "status": "listed",
 "first_seen": "2026-11-24",
 "uptime_days": "2/2"
}