{
 "type": "mcp",
 "name": "The Cable Code",
 "registry_name": "io.github.exquad/thecablecode",
 "also_published_as": [],
 "description": "Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.",
 "url": "https://thecablecode.com/mcp",
 "transport": "streamable-http",
 "website": "https://thecablecode.com/developers",
 "repo": null,
 "ours": false,
 "publisher": "io.github.exquad",
 "categories": [
  "dev-tools",
  "engineering",
  "research"
 ],
 "tests": {
  "tested_at": "2026-11-24T21:39:33.390Z",
  "http_status": 200,
  "initialize": "ok",
  "tools_list": "ok",
  "tool_count": 25,
  "latency_ms": 231,
  "tools_list_ms": 217,
  "protocol_version": "2025-06-18",
  "oauth_discovery": null,
  "server_info": {
   "name": "thecablecode",
   "version": "1.102.0"
  },
  "error": null
 },
 "signals": {
  "github_stars": null,
  "license": null,
  "repo_pushed_at": null,
  "repo_archived": null,
  "npm_downloads_30d": null,
  "adoption_note": null,
  "registry_updated_at": "2026-11-13T08:52:18.701729Z",
  "registry_published_at": "2026-11-13T08:52:18.701729Z",
  "pypi_downloads": "missing"
 },
 "checks": {
  "latency": 100,
  "tool_docs": 100,
  "breadth": 82.9,
  "freshness": 100,
  "license": "missing",
  "adoption": "missing",
  "protocol": 100
 },
 "score": 58.3,
 "missing": [
  "license",
  "adoption"
 ],
 "tools": [
  "decode_cable_code",
  "design_cable",
  "find_equivalents",
  "overhead_conductor",
  "check_cable",
  "extract_datasheet",
  "read_tender",
  "write_specification",
  "design_presets",
  "drum_fit",
  "burial_depth",
  "fire_class",
  "awg_metric",
  "conduit_fill",
  "pull_cable",
  "tray_fill",
  "drum_loading",
  "cold_weather_check",
  "mv_electrical",
  "economic_size",
  "commissioning_sheet",
  "cable_prep",
  "iec60287_rating",
  "degassing_time",
  "equivalence_report"
 ],
 "tool_docs": [
  {
   "n": "decode_cable_code",
   "d": "Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conduct"
  },
  {
   "n": "design_cable",
   "d": "Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its stand"
  },
  {
   "n": "find_equivalents",
   "d": "The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equiv"
  },
  {
   "n": "overhead_conductor",
   "d": "A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code (\"242-AL1/39-ST1A\", EN 50182; \"401-AL0/28-MEHST\", FprEN 50540) or an EN 50182 Annex F table ("
  },
  {
   "n": "check_cable",
   "d": "Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, "
  },
  {
   "n": "extract_datasheet",
   "d": "Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and"
  },
  {
   "n": "read_tender",
   "d": "Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing "
  },
  {
   "n": "write_specification",
   "d": "Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender "
  },
  {
   "n": "design_presets",
   "d": "What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, "
  },
  {
   "n": "drum_fit",
   "d": "Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic "
  },
  {
   "n": "burial_depth",
   "d": "Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rul"
  },
  {
   "n": "fire_class",
   "d": "The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenu"
  },
  {
   "n": "awg_metric",
   "d": "AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation "
  },
  {
   "n": "conduit_fill",
   "d": "NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, a"
  },
  {
   "n": "pull_cable",
   "d": "Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the "
  },
  {
   "n": "tray_fill",
   "d": "NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per "
  },
  {
   "n": "drum_loading",
   "d": "How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. "
  },
  {
   "n": "cold_weather_check",
   "d": "A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknow"
  },
  {
   "n": "mv_electrical",
   "d": "MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its sour"
  },
  {
   "n": "economic_size",
   "d": "Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with"
  },
  {
   "n": "commissioning_sheet",
   "d": "The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to recor"
  },
  {
   "n": "cable_prep",
   "d": "End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kind"
  },
  {
   "n": "iec60287_rating",
   "d": "IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency rating"
  },
  {
   "n": "degassing_time",
   "d": "Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait b"
  },
  {
   "n": "equivalence_report",
   "d": "An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a sta"
  }
 ],
 "passed": true,
 "auth_required": false,
 "fail_reason": null,
 "category_confidence": 0.642,
 "category_source": "classifier",
 "category_scores": {
  "dev-tools": 2.26,
  "design-docs": 1.41,
  "weather": 0.19,
  "finance": 0.1
 },
 "subcategory": "testing-qa",
 "id": "io-github-exquad-thecablecode",
 "listing": {
  "plan": "curated",
  "fee_usd": null,
  "note": "Listing fees are not active. Placement is earned only by test results."
 },
 "status": "listed",
 "first_seen": "2026-11-24",
 "uptime_days": "2/2"
}