The Cable Code

Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.

Status: Listed — passed its latest tests · Score: 58.3/100 · Category: Developer tools & code, Engineering, CAD & hardware, Research, science & academic

Connect: https://thecablecode.com/mcp (streamable-http)

Score breakdown

latency100
tool docs100
breadth82.9
freshness100
licensemissing
adoptionmissing
protocol100

Live test results

tested at2026-11-24T21:39:33.390Z
http status200
initializeok
tools listok
tool count25
latency ms231
tools list ms217
protocol version2025-06-18
oauth discoverymissing
server info{"name":"thecablecode","version":"1.102.0"}
errormissing

Usage and freshness signals

github starsmissing
licensemissing
repo pushed atmissing
repo archivedmissing
npm downloads 30dmissing
adoption notemissing
registry updated at2026-11-13T08:52:18.701729Z
registry published at2026-11-13T08:52:18.701729Z
pypi downloadsmissing

Tools (25)

decode_cable_codeDecode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conduct
design_cableDesign and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its stand
find_equivalentsThe same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equiv
overhead_conductorA bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table (
check_cableCheck a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required,
extract_datasheetRead a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and
read_tenderRead a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing
write_specificationWrite the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender
design_presetsWhat design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it,
drum_fitWhich cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic
burial_depthMinimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rul
fire_classThe lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenu
awg_metricAWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation
conduit_fillNEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, a
pull_cablePull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the
tray_fillNEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per
drum_loadingHow filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources.
cold_weather_checkA place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknow
mv_electricalMV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its sour
economic_sizeEconomic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with
commissioning_sheetThe tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to recor
cable_prepEnd preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kind
iec60287_ratingIEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency rating
degassing_timeDays an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait b
equivalence_reportAn IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a sta

Links: website · JSON · first seen 2026-11-24 · days passed 2/2 · registry name io.github.exquad/thecablecode